Business description of ACUTUS-MEDICAL-INC from last 10-k form

UNITED STATES

SECURITIES AND EXCHANGE COMMISSION

Washington, D.C. 20549

FORM 10-K

(Mark One)

ANNUAL REPORT PURSUANT TO SECTION 13 OR 15(d) OF THE SECURITIES EXCHANGE ACT OF 1934

For the fiscal year ended December 31, 2020

TRANSITION REPORT PURSUANT TO SECTION 13 OR 15(d) OF THE SECURITIES EXCHANGE ACT OF 1934 FOR THE TRANSITION PERIOD FROM                        TO                        

Commission File Number 001-39430

ACUTUS MEDICAL, INC.

(Exact name of Registrant as specified in its Charter)

Delaware

45-1306615

(State or other jurisdiction of

incorporation or organization)

(I.R.S. Employer

Identification No.)

2210 Faraday Ave.,

Suite 100, Carlsbad, CA

92008

(Address of principal executive offices)

(Zip code)

Registrant’s telephone number, including area code: (442) 232-6080

Securities registered pursuant to Section 12(b) of the Act:

Title of each class

 

Trading

Symbol(s)

 

Name of each exchange on which registered

Common stock, par value $0.001 per share

 

AFIB

 

The Nasdaq Stock Market LLC

Securities registered pursuant to Section 12(g) of the Act: None

Indicate by check mark if the Registrant is a well-known seasoned issuer, as defined in Rule 405 of the Securities Act. YES  NO 

Indicate by check mark if the Registrant is not required to file reports pursuant to Section 13 or 15(d) of the Act.  YES  NO 

Indicate by check mark whether the Registrant: (1) has filed all reports required to be filed by Section 13 or 15(d) of the Securities Exchange Act of 1934 during the preceding 12 months (or for such shorter period that the Registrant was required to file such reports), and (2) has been subject to such filing requirements for the past 90 days.  YES  NO 

Indicate by check mark whether the Registrant has submitted electronically every Interactive Data File required to be submitted pursuant to Rule 405 of Regulation S-T during the preceding 12 months (or for such shorter period that the Registrant was required to submit such files).  YES  NO 

Indicate by check mark whether the Registrant is a large accelerated filer, an accelerated filer, a non-accelerated filer, smaller reporting company, or an emerging growth company. See the definitions of “large accelerated filer,” “accelerated filer,” “smaller reporting company,” and “emerging growth company” in Rule 12b-2 of the Exchange Act.

Large accelerated filer

 

  

Accelerated filer

 

Non-accelerated filer

 

  

Smaller reporting company

 

Emerging growth company

 

 

 

 

 

If an emerging growth company, indicate by check mark if the Registrant has elected not to use the extended transition period for complying with any new or revised financial accounting standards provided pursuant to Section 13(a) of the Exchange Act.  

Indicate by check mark whether the Registrant has filed a report on and attestation to its management’s assessment of the effectiveness of its internal control over financial reporting under Section 404(b) of the Sarbanes-Oxley Act (15 U.S.C. 7262(b)) by the registered public accounting firm that prepared or issued its audit report.  

Indicate by check mark whether the Registrant is a shell company (as defined in Rule 12b-2 of the Exchange Act).  YES  NO 

As of June 30, 2020, the last business day of the Registrant’s most recently completed second fiscal quarter, the Registrant’s

equity was not listed on a domestic exchange or over-the-counter market. The Registrant’s common stock began trading on The

Nasdaq Global Select Market on August 6, 2020.

On March 15, 2021, there were 28,095,004 shares of common stock outstanding.

DOCUMENTS INCORPORATED BY REFERENCE

Part III of this Annual Report on Form 10-K incorporates certain information by reference from the definitive proxy statement for the Registrant’s 2021 Annual Meeting of Stockholders to be filed within 120 days of the Registrant’s fiscal year ended December 31, 2020 (the “Proxy Statement”). Except with respect to information specifically incorporated by reference in this Form 10-K, the Proxy Statement is not deemed to be filed as part of this Form 10-K.

Table of Contents

 

 

Page

PART I

 

 

Item 1.

1

Item 1A.

18

Item 1B.

75

Item 2.

75

Item 3.

75

Item 4.

75

 

 

 

PART II

 

 

Item 5.

76

Item 6.

76

Item 7.

77

Item 7A.

93

Item 8.

94

Item 9.

132

Item 9A.

132

Item 9B.

132

 

 

 

PART III

 

 

Item 10.

133

Item 11.

133

Item 12.

133

Item 13.

133

Item 14.

133

 

 

 

PART IV

 

 

Item 15.

134

Item 16

134

Item 1. Business.

Overview

We are an arrhythmia management company focused on improving the way cardiac arrhythmias are diagnosed and treated. Despite several decades of efforts by incumbents in this field, the clinical and economic challenges associated with arrhythmia treatment continue to be a huge burden for patients, providers and payors. We are committed to advancing the field of electrophysiology with a unique array of products and technologies which will enable more physicians to treat more patients more efficiently and effectively. Through internal product development, acquisitions and global partnerships, we have established a global sales presence delivering a broad portfolio of highly differentiated electrophysiology products. Our goal is to provide our customers with a complete solution for catheter-based treatment of cardiac arrhythmias in the geographic markets that we serve.

We design, manufacture and market a range of tools for catheter-based ablation procedures to treat various arrhythmias. Cardiac ablation involves using high-energy radio frequency or extreme cold to target tissue in the heart that is responsible for triggering or sustaining an abnormal heart rhythm. Our product portfolio includes novel access sheaths, transseptal crossing tools, diagnostic and mapping catheters, conventional and contact force ablation catheters (currently available only in our European markets), mapping and imaging consoles and accessories, as well as supporting algorithms and software programs. Our foundational and most highly differentiated product is our AcQMap imaging and mapping system, which offers a paradigm-shifting approach to mapping the drivers and maintainers of arrhythmias with unmatched speed and precision. With the ability to rapidly and accurately identify ablation targets and to confirm both ablation success and procedural completion, we believe our AcQMap System addresses the primary unmet need in electrophysiology procedures today.

While multiple trials have established that cardiac ablation is effective when the source of the arrhythmia is accurately identified and successfully ablated, visualization of various complex arrhythmias and creation of durable ablation lesions remains challenging with long, unpredictable procedure times and inconsistent outcomes. For example, data from large, multi-center trials of cardiac ablation have demonstrated that approximately 30 to 50% of ablations for atrial fibrillation result in arrhythmia recurrence within the first 12 months of the initial ablation procedure. Currently marketed mapping systems are not able to quickly and consistently identify the source of the arrhythmia in more complex cases, which can contribute to these unsatisfactory outcomes. Current competitive mapping systems sequentially collect data, point-by-point, by contacting the heart surface at multiple locations throughout the chamber. This is a time-consuming process that often takes 15 to 20 minutes per map. Additionally, because contact-based mapping relies on a fixed timing reference to sequence the data points, it precludes these systems from being able to quickly and reliably identify the drivers and maintainers of unstable arrhythmias, such as atrial fibrillation, many types of supraventricular tachycardias and certain ventricular arrhythmias.

We designed our AcQMap System to improve procedure efficiency and outcomes by rapidly and accurately identifying ablation targets and confirming both ablation success and procedure completion. Our AcQMap System consists of our single-use AcQMap catheter as well as our console, workstation and proprietary software algorithms. With 48 ultrasound transducers interspersed between 48 biopotential electrodes, our innovative mapping catheter collects the data required to create a comprehensive map of the cardiac anatomy and electrical propagation pathways and patterns in under three minutes, without contacting the chamber wall. Our proprietary software algorithms analyze the biopotential data and are collectively able to map any type of stable or unstable arrhythmia, including atrial fibrillation, as well as all supraventricular tachycardias and ventricular arrhythmias.

We believe that by creating high definition, clinically accurate activation maps of all types of arrhythmias, our AcQMap System offers physicians better decision-making tools for determining where to ablate. Similarly, we believe the speed and ease of creating a map makes it practical for physicians to iteratively map, treat, re-map and adjust additional therapy as needed. We believe these features will drive more efficient and predictable procedures and better outcomes for a broader range of arrhythmias.

We have established a broad portfolio of electrophysiology products that complements our AcQMap System. In addition to our AcQMap System, our commercial product portfolio includes a suite of access devices, our transseptal crossing device and full product lines of diagnostic and, in our European markets, ablation catheters. In our European markets, our portfolio provides our customers with a complete solution—from vascular access to diagnosis and treatment of arrhythmias. In the United States, we are currently seeking regulatory approval for our ablation catheters to complement our portfolio of access and mapping devices. We also recently expanded our portfolio to include the AcQBlate Force gold-tip, irrigated, radiofrequency force sensing ablation catheters and Qubic Force control unit, or AcQBlate Force Sensing Ablation System, which we expect to commercialize following the December 2020 receipt of Conformité Européenne Mark, or CE Mark approval in Europe. Biotronik SE & Co. KG, or Biotronik, had previously performed the BioConcept Study, which was used as the base data for CE Mark submission, and no additional clinical data was required for CE Mark approval. We also plan to commence enrollment in two investigational device exemption, or IDE, trials for U.S. Food and Drug Administration Premarket Approval, or FDA PMA, in the United States during the first half of 2021 with one trial seeking a right atrial typical flutter indication and the second trial seeking a paroxysmal and persistent atrial fibrillation indication. We currently anticipate FDA PMA, and the U.S. commercial launch, of our AcQBlate Force Sensing Ablation System in the second half of 2022 or early 2023. We believe that our ability to offer a broad and differentiated product portfolio will support the adoption and utilization of our AcQMap System and drive an efficient business model. Once an AcQMap console and workstation is established in a customer account, our revenue from that account becomes predominantly recurring in nature and derived from the sale of our portfolio of disposable products used with our system.

We market and sell our electrophysiology products worldwide to hospitals and electrophysiologists that treat patients with arrhythmias. We have strategically developed a direct selling presence in the United States and select markets in Western Europe where cardiac ablation is a standard of care and third-party reimbursement is well-established. In other international markets, we leverage our partnership with Biotronik, a large multi-national, privately-held biomedical technology company with a leading portfolio across cardiac rhythm management, electrophysiology and vascular intervention, to sell and distribute our products. In the United States and Western Europe, our target market is highly concentrated. We plan to leverage the concentrated nature of procedure volumes and the recurring nature of our sales to drive an increasingly efficient commercial model.

Our research and development activities are focused on advancing the field of electrophysiology by increasing the AcQMap System’s utility and seeking approval for additional labeled indications as well as expanding our product portfolio to further improve and simplify the entire procedural experience. Our near-term pipeline includes products that broaden our commercial portfolio, increase functionality and/or reduce costs across catheters, accessory devices, mapping systems and software.

Our Market and Industry

Cardiac arrhythmias, or heart rhythm disorders, are common and can occur when the heart beats too rapidly, too slowly or irregularly. If left untreated, arrhythmias can result in debilitating symptoms, heart failure, stroke and sudden cardiac death.

Atrial fibrillation, or AF, is the most common arrhythmia and is characterized by rapid and irregular activation of the heart. This irregular behavior increases the potential to develop blood clots within the upper chambers of the heart, which can then circulate to other organs, leading to reduced blood flow and strokes. We estimate that there were approximately 475,000 cardiac ablation procedures globally for atrial fibrillation in 2019.

Supraventricular tachycardias, or SVTs, are characterized by a rapid heartbeat in the upper chambers of the heart. These arrhythmias, which include atrial flutter and atrial tachycardia, among others, can arise organically or as a result of an incomplete ablation for atrial fibrillation. We estimate there were approximately 516,000 ablation procedures worldwide for SVTs in 2019.

Ventricular arrhythmias affect the lower chambers of the heart and consist primarily of ventricular tachycardias, or VTs, and premature ventricular contractions, or PVCs. If left untreated, VTs and PVCs can lead to heart failure, ventricular fibrillation and sudden cardiac death. We estimate that there were approximately 90,000 global ablation procedures for ventricular arrhythmias in 2019.

Because currently marketed mapping systems rely on tissue contact and a fixed timing reference to collect and align data in the proper sequence, they are designed to map simple, stable and repetitive arrhythmias, including certain SVTs and VTs. Collecting a critical mass of data points to see even a stable rhythm is time consuming with contact mapping technologies, often taking 15 to 20 minutes per map. In addition, these technologies can only map one rhythm from each data collection session and are not capable of quickly and reliably mapping unstable or complex arrhythmias such as AF, certain VTs, PVCs or many types of SVTs.

Our Solution

We design, manufacture and market a range of tools for catheter-based ablation procedures to treat various arrhythmias. Our foundational and most highly differentiated product is our AcQMap imaging and mapping system which offers a paradigm-shifting approach to mapping the drivers and maintainers of arrhythmias with unmatched speed and precision. With the ability to rapidly and accurately identify ablation targets and to confirm both ablation success and procedural completion, we believe our AcQMap System addresses the primary unmet need in electrophysiology procedures today.

Overview of Our AcQMap System

We developed our AcQMap System to address the key challenges that electrophysiologists face during ablation procedures and remove the barriers to adopting ablation for complex arrhythmia procedures.

Our AcQMap System consists of our AcQMap catheter, console and workstation. With 48 ultrasound transducers interspersed between 48 biopotential electrodes, our innovative mapping catheter collects the data required to create a comprehensive map of the cardiac anatomy and electrical propagation patterns and pathways without contacting the chamber wall. This allows us to create comprehensive diagnostic maps of the chamber anatomy and electrical propagation patterns and pathways in under three minutes. Our proprietary software algorithms analyze the biopotential data and are collectively able to map any type of stable or unstable arrhythmia, including atrial fibrillation, as well as all supraventricular tachycardias and ventricular arrhythmias.