Business description of EBR-SYSTEMS-INC from last 10-k form

In this report, unless otherwise stated or the context otherwise indicates, the terms “EBR Systems,” “EBR,” “the Company,” “we,” “us,” “our” and similar references refer to EBR Systems, Inc. and its consolidated subsidiaries. The EBR logo, and other trademarks, trade names or service marks of EBR Systems, Inc. appearing in this Annual Report on Form 10-K are the property of EBR Systems, Inc. All other trademarks, trade names and service marks appearing in this Annual Report on Form 10-K are the property of their respective owners. Solely for convenience, the trademarks and trade names in this report may be referred to without the ® and ™ symbols, but such references should not be construed as any indicator that their respective owners will not assert their rights thereto.

 

FORWARD-LOOKING STATEMENTS

This Annual Report on Form 10-K (this “Annual Report”) contains forward-looking statements that are based on our management’s beliefs and assumptions and on information currently available to our management. Some of the statements under “Risk Factors,” “Management’s Discussion and Analysis of Financial Condition and Results of Operations,” “Business” and elsewhere in this Annual Report contain forward-looking statements. In some cases, you can identify forward-looking statements by the following words: “may,” “might,” “will,” “could,” “would,” “should,” “expect,” “plan,” “anticipate,” “intend,” “seek,” “believe,” “estimate,” “predict,” “potential,” “continue,” “contemplate,” “possible” or the negative of these terms or other comparable terminology, although not all forward-looking statements contain these words.

These statements involve risks, uncertainties and other factors that may cause our actual results, levels of activity, performance or achievements to be materially different from the information expressed or implied by these forward-looking statements. Although we believe that we have a reasonable basis for each forward-looking statement contained in this Annual Report, we caution you that these statements are based on a combination of facts and factors currently known by us as of the date of this Annual Report and our projections of the future, about which we cannot be certain. Forward-looking statements in this Annual Report include, but are not limited to, statements about:

You should refer to the “Item 1A. Risk Factors” section of this Annual Report for a discussion of other important factors that may cause our actual results to differ materially from those expressed or implied by our forward-looking statements. As a result of these factors, we cannot assure you that the forward-looking statements in this Annual Report will prove to be accurate. Moreover, we operate in a very competitive and rapidly changing environment. New risks and uncertainties emerge from time to time and existing risks and uncertainties may become more material, and it is not possible for us to predict all risks and uncertainties that could have an impact on the forward-looking statements contained in this Annual Report.

 2 

In addition, statements that “we believe” and similar statements reflect our beliefs and opinions on the relevant subject. These statements are based upon information available to us as of the date of this Annual Report, and although we believe such information forms a reasonable basis for such statements, such information may be limited or incomplete, and our statements should not be read to indicate that we have conducted a thorough inquiry into, or review of, all potentially available relevant information. These statements are inherently uncertain, and investors are cautioned not to unduly rely upon these statements. Furthermore, if our forward-looking statements prove to be inaccurate, the inaccuracy may be material. In light of the significant uncertainties in these forward-looking statements, you should not regard these statements as a representation or warranty by us or any other person that we will achieve our objectives and plans in any specified time frame, or at all. We undertake no obligation to publicly update any forward-looking statements, whether as a result of new information, future events or otherwise.

Item 1. Business

Overview

EBR Systems, Inc., a Delaware corporation incorporated in 2003, is a U.S. based medical device company that is developing the WiSE CRT System, an implantable cardiac pacing system able to provide stimulation to endocardial heart tissue for the correction of heart rhythm conditions without requiring the use of wires or leads. This implantable, investigational device delivers left-ventricle endocardial pacing for cardiac resynchronization therapy (“CRT”), without the use of wires or leads going into the heart. An investigational device is one that has not been cleared or approved for commercial use by the U.S. Food and Drug Administration (the “FDA”). The left ventricle (“LV”) is a chamber of the heart responsible for pumping blood through the aorta to the rest of the body, such that ‘left-ventricle endocardial’ pacing refers to electrical pacing delivered inside the left ventricle of the heart. Conventional cardiac rhythm management (“CRM”) systems use leads to conduct electricity from an implantable pulse generator (“IPG”) to electrodes that deliver therapeutic electric pulses to heart tissue. While leads are a critical part of most CRM systems, they have long been recognized as a primary shortcoming of these systems and are a leading cause of device failure. Our leadless system is designed to address this shortcoming.

Our proprietary WiSE CRT technology is engineered to benefit patients who have not seen success with conventional CRT or face high complication risks. Conventional CRT has limitations related to the need for lead placement and complication risks of occlusion, infection or concurrent illness. By eliminating lead requirements for left ventricular pacing, WiSE CRT introduces a novel approach to cardiac pacing, with the potential to transform CRT delivery. If approved by the FDA, our system would allow clinicians to provide CRT for patients where a LV lead has failed or is deemed high-risk by their doctor. A patient in whom standard CRT upgrade is not advisable due to known relative contraindication to coronary sinus (“CS”) lead implant would be deemed high-risk by their doctor.

The initial focus of our WiSE CRT technology is to serve as an adjunct to existing implanted cardiac devices, providing CRT to those for whom traditional methods have failed or are not viable. In support of capturing this opportunity, WiSE CRT has been granted a Breakthrough Device Designation (“BDD”) by the FDA, which provides us with greater access to the FDA during the premarket review phase, a prioritized review process, and potentially up to three years of favorable reimbursement coverage in the U.S. following such approval. We completed a pivotal clinical study, SOLVE-CRT (Stimulation of the Left Ventricular Endocardium for Cardiac Resynchronization Therapy) and submitted the final module of our modular pre-market approval (“PMA”) submission on August 28, 2024. For a more comprehensive discussion of the SOLVE-CRT study, see “SOLVE-CRT Clinical Trial” below.

Products

The WiSE CRT System, the Company’s only product candidate, is an implantable cardiac pacing system capable of delivering pacing level energy to the heart without using a lead/ wire. The technology used to achieve this leadless pacing is based on converting ultrasound energy to electrical energy. The system consists of a battery connected to an ultrasound transmitter that is implanted subcutaneously and the electrode implanted in the LV endocardium. The system requires a co-implant (e.g., pacemaker, defibrillator, or CRT) capable of right ventricular (“RV”) pacing. The transmitter senses the RV pacing spike of the co-implant and within approximately five milliseconds emits an ultrasonic pulse to the electrode, which converts the ultrasound energy received to electrical energy at sufficient amplitudes to pace/ stimulate cardiac tissue. The intensity of the ultrasound energy used is very low, even in comparison to levels used for echocardiographic imaging.

 3 

The leadless WiSE Electrode essentially replaces the pacing function of a traditional LV lead. The WiSE CRT System is used in conjunction with a typical, commercially available implanted pacemaker, implantable cardioverter defibrillator (“ICD”), or CRT device with an RV pacing function. Immediately after sensing an RV pacing output from the co-implanted device, the WiSE CRT System triggers an ultrasound pulse targeted at the Electrode to pace the left ventricle. The sequence of sensing, transmitting, receiving, and stimulating the left ventricle is essentially simultaneous with the co-implanted device’s RV pacing output and thus provides biventricular (“BiV”) pacing analogous to CRT pacing devices.

Components of the WiSE CRT System include the Delivery Sheath and Electrode Catheter which delivers the Electrode, the Pulse Generator (Transmitter and Battery), and the Programmer (Figure 1.1).

Figure 1.1 How WiSE CRT System Provides Leadless Cardiac Pacing

 4 

The SOLVE-CRT investigational device exemption (“IDE”) study is a prospective, multicenter trial consisting of an initial randomized, double-blind part and a subsequent single-arm part. It was originally designed as a randomized, multinational, double-blind study to enroll 350 patients from up to 45 centers. Patients were enrolled if they received right ventricular (“RV”) pacing from a prior pacing implant and either did not have a fully functioning CRT system because of lead issues (Previously Untreatable [“PU”]), did not respond to CRT therapy (Non-Responders [“NR”]), or were considered high risk for a standard CRT upgrade (High-Risk Upgrade [“HRU”]), which included those with a cardiac pacemaker or intracardiac defibrillator (“ICD”) requiring upgrade to CRT.

The first patient was enrolled in the SOLVE-CRT study in January 2018. Enrollment was severely impacted by the COVID-19 pandemic and was paused in March 2020 after 108 patients were enrolled. At that time, the investigators worked with the FDA to revise the clinical protocol, implementing a single-arm, non-randomized part to complete the study. Central to this strategy was a differentiation of the three original patient groups and the requirements for demonstration of safety and efficacy. For the patients in the PU and HRU groups, CRT was an approved therapy, and the WiSE CRT System could be viewed as an alternate method of providing CRT when conventional CRT was not possible, so a Single-Arm study with pre-specified objective performance goals was appropriate. In contrast, the NR group had suboptimal responses to conventional CRT due to a diverse set of pathophysiologic mechanisms. Thus, there was a different threshold for scientifically acceptable evidence for safety and effectiveness, and this group was excluded from the study continuation.

The modified study was designed to enroll up to 300 patients with a pre-specified interim analysis with early stopping rules after enrolling 183 patients. All 183 patients (PU/HRU/NR) were included in the safety analysis while only the PU and HRU patients (n = 100) were included in the efficacy analysis. The primary safety endpoint was the freedom from device- or procedure-related complications (Type I). The primary efficacy endpoint was the reduction in left ventricular systolic volume (“LVESV”). LVESV is a key marker of advanced heart failure and goes up as the HF progresses. All versions of the study protocol were approved by relevant institutional review boards and the FDA under an IDE application. All patients provided written informed consent.

At the interim analysis, the primary 6-month efficacy endpoint was met with a 16.4% (95% confidence interval [“CI”], 11.7% to 21.0%) reduction in mean LVESV, significantly favorable to the 9.3% performance goal (p = 0.003). The primary 6-month safety endpoint was met with an 80.9% (148/183 participants) (lower boundary of the one-sided 98.8% CI, 73.4%) rate of freedom from device- or procedure-related (Type I) complications, significantly favorable to the 70% performance goal (p < 0.001). Since both the primary efficacy and safety endpoints met the pre-specified stopping rules for interim analysis, the trial was concluded early for success.

Secondary endpoints included an acoustic pacing capture threshold (“APCT”) of < 2.9 mJ achieved in 95.2% of participants and APCT stability achieved in 81.3% of participants, indicating that the WiSE CRT System was capable of delivering CRT in the majority of patients enrolled in the study and that the energy required to deliver CRT remained stable. In addition, 93.1% of participants achieved a mean percent BiV pacing, 46.1% achieved an increase in Left ventricular ejection fraction (“LVEF”) ≥ 5%, and 65.5% achieved an increase of ≥ 5 points in Kansas City Cardiomyopathy Questionnaire.

We are seeking to demonstrate with the SOLVE-CRT study that leadless left ventricular endocardial pacing (“LVEP”) with the novel WiSE CRT System is feasible, safe, and effective for delivering CRT in patients with advanced HF.

Clinical Conclusion

Subject to the review and determination by the FDA, we believe the performance and safety of the WiSE CRT System is supported by results of the SOLVE-CRT pivotal clinical trial, and peer-reviewed clinical literature. The System has a high implant success rate and delivers significant benefit to moderate to severe HF patients, including improved clinical and functional status and reverse remodeling. Further, complication rates observed with the WiSE CRT System are similar to those observed with other approaches to delivering CRT. The risks associated with the use of the System are acceptable when weighed against the potential benefits to the indicated patient populations. This is of particular importance as the patient populations treated in the EBR-sponsored studies have failed or not responded to conventional CRT and have a poor prognosis. Providing clinical benefit to these high-risk patients shows that the WiSE CRT System can meet the identified unmet clinical need for novel approaches to delivering CRT for the treatment of HF.

 5 

Further, we believe the design strategy for the WiSE CRT System results in a leadless device that is 95% smaller by volume compared to commercially available leadless pacemakers, such as Medtronic’s Micra or Abbott’s Aveir. Consequently, subject to approval by the FDA, we believe WiSE CRT will be the only therapy demonstrated in clinical study that can deliver LVEP and potentially broaden the spectrum of patients who could benefit from CRT.

Status of the FDA Review

We submitted the final module of our PMA submission on August 28, 2024. Under standard review, the FDA has 180 days to review the PMA. In January 2025, the FDA completed the manufacturing site Pre-Approval Inspection (“PAI”) with no Form FDA 483 observations. Thus, subject to FDA review and approval, and pre-commercial activities described under “Markets and Distribution” below, we expect to commercially launch the WiSE CRT System in the U.S. in 2025.

If approved by the FDA and other regulatory authorities, we intend to commercially launch WiSE with the focus on driving adoption of WiSE at key, high-volume, luminary sites within the U.S. to be followed by select, high-volume sites in markets outside the U.S. (“OUS”) that we are targeting after evaluating regulatory and reimbursement considerations.

We plan to implement a phased Limited Market Release (“LMR”), with the following phases:

LMR Phase 1: Initial Target Accounts

LMR Phase 2: Expansion and Optimization